NVX DIGITAL ENGINEERING

Solar Calculator

Don't know your kWh? Enter your average electricity bill. NVX converts every input to kWh/month before sizing the photovoltaic system.

1. Tell us what you know

Energy consumed each month, in kWh.
Default BRL example: R$1.00/kWh. You can replace it with the actual tariff.
Total annual consumption in kWh.
V1 stores location for project reference. Irradiation automation comes in a future layer.

2. Customer / Site / Roof Mapping

CONFIRMED PROJECT LOCATION REQUIRED Enter real latitude and longitude. Example values are no longer treated as project data.
NVX ROOF MAP ENGINE V2 — CLICK THE ROOF Use address/GPS to locate the site. For V4.3 you can click directly on the roof-plan canvas to create/edit a polygon, or paste precise GPS corners from Google Earth/Maps.
Click roof corners clockwise. The canvas is a local planning surface; use pasted GPS points below for geodesic area accuracy.
Set the approximate real-world width represented by the planning canvas. V4.3 uses this to estimate clicked polygon area.
IMPORT KML / KMZ WORKFLOW Export the roof polygon from Google Earth as KML. In this V4.4, paste the KML text below or paste the extracted <coordinates> content.
No KML imported.
POLYGON POINTS0
POLYGON AREA—m²
MAIN ORIENTATION—approx. azimuth
CLICKED ROOF AREA—m² local estimate
V4.2 calculates geodesic roof area from GPS polygon points. Satellite imagery remains in Google Maps/Earth; embedded satellite mapping can be connected later with a map API.
Total mapped area in m². Preliminary V1 factor to account for setbacks, obstacles, access and unusable zones. Effective planning area per module, including preliminary spacing. Default V1: 2.8 m²/module.

3. Multi-Roof / Multi-Surface Mapping

NVX MULTI-SURFACE ENGINE V2 Add independent roofs, garages, carports, canopies, warehouses or ground-mount areas. Each surface keeps its own geometry, azimuth, tilt and KML/GPS polygon.
TOTAL SURFACES0
TOTAL GROSS AREA0.0m²
TOTAL USABLE AREA0.0m²
TOTAL MODULE CAPACITY0modules
WEIGHTED ORIENTATION FACTOR—
MULTI-ROOF STATUSNOT MAPPED
DUPLICATE POLYGONS0excluded from totals

4. Solar Path & Roof Orientation

NVX SOLAR PATH ENGINE V1 Uses latitude, date and local solar geometry to estimate sunrise/sunset direction, solar-noon elevation and a preliminary roof-orientation factor.
0° North • 90° East • 180° South • 270° West.
Preliminary roof inclination.
SUNRISE AZIMUTH—degrees
SUNSET AZIMUTH—degrees
SOLAR NOON ELEVATION—degrees
DAY LENGTH—hours
ORIENTATION FACTOR—preliminary
ROOF SOLAR STATUS—orientation quality
ORIENTATION SOURCE—manual or mapped surfaces
V4.5 solar geometry is a preliminary clear-sky orientation model. It does not yet include terrain horizon, nearby shading, weather files or bankable irradiation datasets.

5. Engineering assumptions

Watts per module. Default: 600 W. Estimated monthly generation in kWh per installed kWp. Default V1: 130 kWh/kWp/month. Default V1: 2.6 m² per module.

6. BESS & Financial assumptions

BESS V1 uses a configurable share of average daily consumption. Editable commercial assumption. Default V1 is only a placeholder, not a market quotation. Editable placeholder for preliminary scenario analysis.

7. Preliminary system result

Enter your data and click CALCULATE.
STANDARDIZED CONSUMPTION—kWh / month
RECOMMENDED PV SYSTEM—kWp installed
SUGGESTED INVERTER—kW AC
INVERTER RANGE ±20%—kW AC selection window
DC / AC RATIO—target ≈ 1.20
INVERTER STATUS—preliminary selection
PV MODULES REQUIRED—modules
USABLE ROOF AREA—m²
MAX MODULES ON ROOF—preliminary capacity
ROOF FIT STATUS—physical vs energy sizing
MULTI-ROOF SURFACES—independent roof faces
MULTI-ROOF CAPACITY—total modules across surfaces
APPROXIMATE PV AREA—m²
ESTIMATED MONTHLY GENERATION—kWh / month
ESTIMATED ANNUAL GENERATION—kWh / year
ORIENTATION-CORRECTED GENERATION—kWh / year preliminary
ESTIMATED MONTHLY ENERGY VALUE—based on tariff
ESTIMATED ANNUAL ENERGY VALUE—orientation-aware when location is valid
FINANCIAL ENERGY BASIS—generation used for savings/payback

8. BESS & Financial result

PRELIMINARY BESS—kWh usable target
ESTIMATED PROJECT INVESTMENT—editable assumptions
YEAR-1 ENERGY VALUE—gross preliminary value
SIMPLE PAYBACK—years
5-YEAR ENERGY VALUE—with tariff escalation
10-YEAR ENERGY VALUE—with tariff escalation
20-YEAR ENERGY VALUE—with tariff escalation
25-YEAR ENERGY VALUE—with tariff escalation

9. NVX Diagnostics

Location EngineCHECK
GPS Polygon EngineCHECK
Duplicate Polygon EngineCHECK
Solar Path EngineCHECK
PV / Inverter EngineREADY
BESS EngineREADY
Financial EngineCHECK
BuildV4.8.7.2 LOCATION + EARTH FIX

10. NVX Proposal Dashboard

Consumption × Solar Generation

Annual Energy Value Projection

Investment × Cumulative Energy Value

NVX PROJECT SUMMARY

PV SYSTEM—
MODULES—
INVERTER—
BESS—
INVESTMENT—
PAYBACK—
ROOF CAPACITY—
ACTIVE SURFACES—
CARPORT SURFACES—
KML/GPS SURFACES—
DUPLICATE SURFACES—
SITE STATUS—
ROOF POLYGON—
ORIENTATION—
MAPPING SOURCE—
ROOF SOLAR FACTOR—
SOLAR PATH—
FINANCIAL BASIS—
ORIENTATION SOURCE—

Preliminary proposal generated from calculator assumptions. Final engineering, equipment selection, commercial quotation and financing terms require validation.

NVX STANDARD
Every customer input is converted first to kWh/month. This is the common engineering basis for Solar PV, BESS, EV Charging, HVAC and Monitoring.
Preliminary engineering estimate only. Final sizing depends on irradiation, orientation, shading, utility rules, tariffs, taxes, equipment selection and engineering validation.